JOERNS GmbH  Phone: +49(0) 5691-6287-0
DEFax: +49(0) 5691-6287-29
  Contact: mailto: JOERNS GmbH

Fume- Gas- and Dust- Extraction Systems

Dgital Extraction Systems
9000-1500i / 9000-2000i

Dgital Extraction System 9000-1500i / 9000-2000i

Structure schematics
  1. Air inlet (Left)
  2. Labyrinth Pre-filter
  3. Main Filter (HEPA location)
  4. Main Filter (Carbon location)
  5. Clean air returned (Rear)
  6. Filter locking handle
  7. Filter identification label

Construction:

Precision engineered brushed stainless steel units.
High performance continuous run motors.
Mounted on castors for mobility.

Digital Control System

A dedicated control, monitoring and display system unique to Purex fume extractors.
All functions are fully automatic, all the user has to do is set the appropriate airflow on installation.
The features of this system are designed to:

  • Lower energy consumption by using variable speed motors and automatic flow control
  • Increase filter life by using the optimal extraction rate
  • Further protect people by constantly monitoring exhaust emissions
  • Interface with other equipment e.g. a laser
  • Maintain a constant extraction rate to prevent fume escape or damage to equipment.

In the case that in the process the generation of large quantities of particles, in addition, the installation of an Inline-filter is recommended.

Features

  • Automatic electronic flow control - maintains a constant extraction rate even as the filter blocks
  • Adjustable airflow
  • Clear and informative graphic display
  • Gas and Particle Sensors on the exhaust
  • Low capital and running costs
  • Quick change patented Labyrinth pre-filters deliver longer filter life
  • Submicronic (HEPA) filtration removes 99.997% of particles down to 0.3 microns
  • Activated carbon filtration removes harmful gas
  • Simple to install and quiet in operation
  • Easy to relocate and precision made from stainless steel
  • Optional: Machine interfacing
    • Start/Stop Control: Extraction unit starts/stops when a connected piece of equipment is switched ON/OFF
    • Filter Blocked Warning: A signal is sent to a connected piece of equipment to trigger an alert or to shut it down
    • Remote ON/OFF Switch: 5M cable & switch

1500i/2000i standard filters
Filter typFilter descriptionCode
Main filterHEPA/Activated carbon110.615
Main filterActivated carbon110.610
Main filterHEPA/Carbon, double activated110.614
Main filterCleanroom110.632
Pre filterPad F5200.280
Pre filterLabyrinth F6111.037
Pre filterLabyrinth F8/F9 Composite111.099


Technical specifications1500i2000i
Part number103.086.151.0DV103.070.220.10D
Voltage230V ±10%400V 3Ph+N
Wattage1,5kW3,0kW
Frequency50/60Hz50/60Hz
Sound rating59dBA59dBA
Flowrate (max)1700m³/h2200m³/h
Vaccum (max)4,77kPa6,28kPa
Dimesions wxdxh725x726x1400mm725x726x1400mm
Weight (incl. filters)150kg150kg
Hose connection Ø150mm150mm