JOERNS GmbH  Phone: +49(0) 5691-6287-0
DEFax: +49(0) 5691-6287-29
  Contact: mailto: JOERNS GmbH

Fume- Gas- and Dust- Extraction Systems

Interfacing Cables

The systems provide interfaces for correspondence with connected machines or laser controls.

The options include: Remote on-off and alarm for failures of the extraction function.

4 way Mini Bulgin Code: 105.097
4 Pin Mini BulginPin configuration
ALARM
PINS 1 + 2 = VOLT FREE ALARM OUTPUT CONTACTS
REMOTE START
VOLT FREE CONTACTS REQUIRED TO OPERATE
PIN 3 = REMOTE START INPUT SIGNAL
PIN 4 = +12V DC

6 way Bulgin Code: 105.103
6 Pin BulginPin configuration
ALARM
PINS 1 + 4 = VOLT FREE ALARM OUTPUT CONTACTS
REMOTE START
VOLT FREE CONTACTS REQUIRED TO OPERATE
PIN 3 = REMOTE START INPUT SIGNAL
PIN 5 = +12V DC
PIN 2 + 6 = NOT USED

5 way XLR Neutric Code: 105.105
5 Pin XLR NeutricPin configuration
ALARM
PINS 1 + 4 = VOLT FREE ALARM OUTPUT CONTACTS
REMOTE START
VOLTAGE SIGNAL REQUIRED TO OPERATE
PIN 2+3 (LINKED) = REMOTE START INPUT SIGNAL
PIN 5 = 0V DC

6 way Lumberg Code: 105.096
6 Pin LumbergPin configuration
ALARM
PINS 1 + 6 = VOLT FREE ALARM OUTPUT CONTACTS
PINS 3 + 4 = VOLT FREE ALARM OUTPUT CONTACTS
REMOTE START
VOLTAGE SIGNAL REQUIRED TO OPERATE
PIN 5 = +12VDC/+24VDC REMOTE START INPUT SIGNAL
PIN 2 = 0V DC INPUT

7 way Lumberg Code: 105.098
7 Pin LumbergPin configuration
ALARM
PINS 3 + 4 = VOLT FREE ALARM OUTPUT CONTACTS
REMOTE START
VOLTAGE SIGNAL REQUIRED TO OPERATE
PIN 1 = +12VDC/+24VDC REMOTE START INPUT SIGNAL
PIN 2 = 0V DC INPUT
PIN 5 + 6 = LINKED
PIN 7 = NOT USED

9 way RS232 female Code: 105.106
9 Pin RS232 femalePin configuration
ALARM
NO ALARM OUTPUT
REMOTE START
VOLTAGE SIGNAL REQUIRED TO OPERATE
PIN 2 = 0V DC
PIN 3 = +12VDC/+24VDC REMOTE START INPUT SIGNAL

9 way RS232 male Code: 105.107
9 Pin RS232 malePin configuration
ALARM
PIN 3 = +12VDC/+24VDC ALARM OUTPUT
REMOTE START
VOLTAGE SIGNAL REQUIRED TO OPERATE
PIN 1 = REMOTE START INPUT SIGNAL
PIN 9 = 0V DC

9 way RS232 male Code: 105.104
9 Pin RS232 malePin configuration
ALARM
PINS 1 + 2 = VOLT FREE ALARM OUTPUT CONTACTS
REMOTE START
VOLT FREE CONTACTS REQUIRED TO OPERATE
PIN 3 = REMOTE START INPUT SIGNAL
PIN 4 = +12V DC

No Connector Code: 105.108
No Connector
ALARM
Red and blue wires = alarm signal Output via a set of volt free contacts inside Purex extractor
REMOTE START
Yellow and green wires = remote start stop Volt free contacts required to close these wires to start (+12VDC signal)

Remote ON/OFF Switch Code: 105.114
Remote ON/OFF Switch
Now you can easily switch your Purex fume extractor on or off from up to 5m away.
This is particulary useful if your fume extractor is tucked away under a bench or in a cupboard where it cannot easily be accessed.
This feature is also useful if the work you do is not continuous e.g. intermittent hand soldering as you will be saving energy by turning the extractor off.

All cables are supplied in 5m length.